Standard Test Procedure Fee ($)
RCT–ASR–STP–0100—Determination of strength of hoses and couplings, type C and CE supplied-air respirators 150
RCT–ASR–STP–0101—Determination of tightness of hoses and couplings, type C and CE supplied-air respirators 150
RCT–ASR–STP–0102—Determination of nonkinkability of hoses, type C and CE supplied-air respirators 150
RCT–ASR–STP–0103—Determination of gasoline permeation of hoses and couplings, type C and CE supplied-air respirators 450
RCT–ASR–STP–0104—Determination of air-regulating valve 100,000 cycles performance, demand and pressure-demand type C and CE supplied-air respirators 3,000
RCT–ASR–STP–0105—Determination of airflow, continuous flow type C and CE supplied-air respirators 300
RCT–ASR–STP–0105A—Determination of airflow, demand and pressure-demand type C and CE supplied-air respirators 300
RCT–ASR–STP–0106—Determination of inhalation airflow resistance, pressure-demand type C and CE supplied-air respirators 150
RCT–ASR–STP–0107—Determination of exhalation airflow resistance, pressure-demand type C and CE supplied-air respirators 150
RCT–ASR–STP–0108—Determination of inhalation airflow resistance, demand type C and CE supplied-air respirators 150
RCT–ASR–STP–0109—Determination of exhalation airflow resistance, demand type C and CE supplied-air respirators 150
RCT–ASR–STP–0110—Determination of gas-tightness test, isoamyl acetate (IAA), type C and CE supplied-air respirators 450
RCT–ASR–STP–0111—Determination of air velocity and noise levels—sound level, type C and CE supplied-air respirators 450
RCT–ASR–STP–0112—Determination of the level of protection provided by abrasive blast, type CE supplied-air respirators using a challenge aerosol of NaCl (sodium chloride) or corn oil 450
RCT–ASR–STP–0113—Determination of airflow resistance—continuous-flow, type C and CE supplied-air respirators 150
RCT–ASR–STP–0114—Determination of sound-level measurement—escape, open-circuit self-contained breathing apparatus using hoods or helmets 450
RCT–ASR–STP–0115—Determination of rated service time—constant-flow, escape, open-circuit self-contained breathing apparatus 150
RCT–ASR–STP–0116—Determination of airflow resistance—continuous-flow, escape, open-circuit self-contained breathing apparatus with hoods 150
RCT–ASR–STP–0117—Determination of positive pressure—closed-circuit, pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0118—Determination of low temperature operation—minimum temperature per applicant, open-circuit self-contained breathing apparatus 1,200
RCT–ASR–STP–0119—Determination of low-temperature operation—minimum temperature per applicant, combination open-circuit self-contained breathing apparatus and type C and CE supplied-air respirators 1,200
RCT–ASR–STP–0120—Determination of positive pressure—open-circuit, pressure-demand self-contained breathing apparatus 75
RCT–ASR–STP–0121—Determination of rated service time—open-circuit, demand and pressure-demand, self-contained breathing apparatus 75
RCT–ASR–STP–0121A—Determination of rated service time—closed-circuit, demand and pressure-demand, self-contained breathing apparatus 75
RCT–ASR–STP–0122—Determination of exhalation breathing resistance—open-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0123—Determination of gas flow measurements—open-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0124—Determination of remaining service life indicator—open-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0124A—Determination of alarm pressure—closed-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0125—Determination of gas tightness—isoamyl acetate (IAA)—self-contained breathing apparatus with facepieces and mouthpieces 750
RCT–ASR–STP–0125A—Determination of gas tightness—isoamyl acetate (IAA)—self-contained breathing apparatus with hoods or helmets 750
CT–ASR–STP–0126—Determination of by-pass valve flow—open-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0127—Determination of by-pass valve flow—closed-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0128—Determination of accuracy of gauge—self-contained breathing apparatus 150
RCT–ASR–STP–0132—Determination of inhalation breathing resistance—open-circuit, demand, self-contained breathing apparatus 150
RCT–ASR–STP–0133—Determination of exhalation breathing resistance—open-circuit, pressure-demand, self-contained breathing apparatus using two second stage regulators 150
RCT–ASR–STP–0134—Determination of gasoline permeation test on breathing bags—closed-circuit, self-contained breathing apparatus 750
RCT–ASR–STP–0135—Determination of inhalation and exhalation breathing resistance—closed-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0136—Determination of demand gas flow—closed-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0137—Determination of continuous gas flow on constant flow with demand flow—closed-circuit, self-contained breathing apparatus 450
RCT–ASR–STP–0138—Determination of safety relief valve operation—closed-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0139—Determination of facepiece carbon dioxide concentrations—self-contained breathing apparatus 450
RCT–ASR–STP–0140—Man tests—self-contained breathing apparatus 3,000
RCT–ASR–STP–0141—Man test number 5—closed-circuit, self-contained breathing apparatus 150
RCT–ASR–STP–0142—Determination of vibration (Ro-Tap test) for man test number 1—escape, closed-circuit, demand, self-contained breathing apparatus 750
RCT–ASR–STP–0143—Determination of low-temperature operation—minimum per manufacturer—closed-circuit, self-contained breathing apparatus 1,200
RCT–ASR–STP–0144—Determination of continuous gas flow on constant flow—closed-circuit, self-contained breathing apparatus 300
RCT–ASR–STP–0145—Determination of sound level measurements for remaining service life indicators—self-contained breathing apparatus 750
RCT–ASR–STP–0146—Determination of diaphragm over-pressurization—open-circuit, self-contained breathing apparatus with belt mounted regulators and breathing tubes 300
RCT–ASR–STP–0147—Determination of mode transfer test—combination, open-circuit self-contained breathing apparatus and supplied-air respirators (SCBA/SAR) 150
RCT–ASR–STP–0148—Determination of remote gauge leak-flow test—open-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0148A—Determination of remote gauge leak-flow test—closed-circuit, demand and pressure-demand, self-contained breathing apparatus 150
RCT–ASR–STP–0155—Man test number 6—self-contained breathing apparatus using liquefied gas 2,400